Q: Every now and then, my optical driver's Test Unit Ready command, which goes through the SCSI Manager, returns zero on the status byte, but two on the message byte. This is strange, because there's no cartridge inserted. Is something wrong with the SCSI Manager? A: There is an identified problem in the SCSI chip on the Macintosh Quadra 700 and 900. The National 53c96 chips used in these models do something the SCSI Manager doesn't expect -- they sometimes retain a byte in the chip's onboard FIFO. As a result (in some cases), the SCSI Manager retrieves the stuck byte as the Status byte, and the Message byte as the Status byte, instead of retrieving the Status and Message bytes from the drive it just posted a command to. Odd things may happen as a result of this anomaly. For instance, some users report that they can't get CD-ROM drives to work with Macintosh Quadra 900s, and some users also find that, periodically, they get "Can't read drive X" messages on the desktop.
The problem occurs with CD-ROM drives and other removable-media devices, such
as SyQuest drives. Since these devices may or may not have media inserted,
their drivers typically poll devices that don't have media inserted, looking
for newly inserted media. Often, they do this by issuing a This is the command sent to the CD-ROM drive:
The last byte (SCSI command such as Apple has implemented a SCSI Manager fix for this problem in System 7.1 and later. |